Damp investigations & specialist repairs · Across London, also serving Surrey0208 212 7331
Our work

Photographs from real jobs.

Explore genuine survey findings and remedial work across London, including a Fulham condensation investigation, a Chiswick pointing defect, damp repairs, basement waterproofing and bathroom ventilation projects.

Battersea · Project photographs

Penetrating damp: drying out, re-rendering and plastering.

On this Battersea job, Damp Proofing Services dealt with a penetrating damp issue. The affected wall was dried out, re-rendered and plastered. These three photographs show the same room through the work.

Exposed brick walls beside a window during penetrating damp works in Battersea

Before: exposed brickwork

The affected wall with the brickwork exposed, before re-rendering.

Keyed render coat on the same Battersea room walls before plastering

During: re-rendering

A new render coat applied and keyed ahead of plastering.

Freshly plastered walls beside the window after penetrating damp works in Battersea

After: freshly plastered

The same walls after replastering, before decoration.

The final photograph shows the plastering stage, not a decorated finish or a long-term follow-up.

About penetrating damp investigations
Survey example · Shepherd’s Bush

Investigating moisture around a skylight.

At a property in Shepherd’s Bush, we picked up elevated moisture readings around a skylight. We used thermal imaging to highlight temperature anomalies, then a drone to inspect the roof externally for visible defects and help advise the customer on next steps.

  1. Check the internal symptoms. Moisture readings around the skylight identified an area requiring further investigation; a reading alone does not establish the cause.
  2. Compare the thermal pattern. Thermal imaging highlighted temperature differences around the affected area. These can guide investigation, but the camera does not directly see water or prove a leak.
  3. Look at the roof externally. The drone provided views of the skylight, roof covering and nearby junctions that were difficult to assess from the ground.
  4. Advise on next steps. We considered the internal findings alongside the external inspection to inform our advice, rather than recommending treatment from a moisture reading alone.

This is an investigation example, not a completed repair or a guarantee that a specific defect caused the damp. Concealed details may still require closer inspection. Drone surveys are subject to suitability, weather and permissions and are scoped separately from the standard damp and timber survey.

About our drone roof and high-level inspections
Internal skylight views and external drone footage from the Shepherd’s Bush survey. Press play to watch with sound.
Pimlico · Bathroom floor repair

Failed floor grout and a leak into the flat below.

At this Pimlico property, failed grout on the bathroom floor was associated with a leak affecting the neighbour’s flat downstairs. We stripped out the affected flooring, dried out the area, reboarded, installed a DITRA mat and retiled with epoxy grout.

Rebuild the floor, rather than cover the symptoms.

The work went beyond patching the grout: removing the affected layers allowed the floor to dry before it was rebuilt. The DITRA mat provides an uncoupling layer beneath the tiles, helping accommodate differential movement between the tiled finish and the substrate. Epoxy grout provides a low-water-absorption, durable joint finish.

Grout alone is not a complete waterproofing system. The substrate, membrane joints, edges, penetrations and movement joints all need suitable detailing. A DITRA installation’s waterproofing performance depends on the complete system and its installation, not simply the presence of the mat.

Bathroom floor tiles lifted around a toilet during strip-out in Pimlico

Lifting the existing floor

Removing tiles and the underlying layers exposed the affected floor construction.

Removal of bathroom flooring and damaged backing near the doorway in Pimlico

Removing damaged layers

The floor was opened up at the doorway as part of the strip-out.

Exposed bathroom floor substrate and removed tile backing beside a bath in Pimlico

Exposing the substrate

The opened-up floor before drying and rebuilding.

Cracked and damaged painted surface associated with the Pimlico bathroom leak

Associated damage

A supplied photograph of the damage associated with the leak.

Completed grey tiled bathroom floor around a bath and toilet in Pimlico

The retiled floor

The finished floor after reboarding, installing a DITRA mat and retiling with epoxy grout.

These photographs show strip-out, associated damage and the finished tiled floor. Drying, new boarding and the DITRA installation are described from the work carried out; those stages are not pictured.

Wimbledon · Damp walls behind dry lining

Why covering a damp wall with plasterboard can hide—not solve—the problem.

At this Wimbledon property, damp masonry had been covered with plasterboard fixed using drywall adhesive, often called “dot and dab”. Moisture-related patches and deterioration appeared on the finished surface. A new lining does not repair the moisture source, and adhesive dabs are not a waterproof barrier.

Patchy painted plasterboard surface above timber skirting
Visible patches on the finished lining. Their appearance alone does not identify the moisture source or salt content.
Blistered and deteriorating wall finish beneath a window beside electrical sockets
Deterioration of the decorated surface beneath a window. Further investigation is needed behind the finish.

How moisture and salts can reach the surface

Where porous adhesive contacts damp masonry, it can provide a capillary route for liquid water into the lining. That water can dissolve soluble salts already present in the wall and carry them towards the surface. When water evaporates, salts may be left in the adhesive, board or finish, contributing to recurring patches and damage.

Some salts, including certain chlorides and nitrates, are hygroscopic: they attract water vapour from humid air. Contaminated finishes can therefore become damp again even after the original water entry has been reduced. Not every salt behaves this way, and a white deposit or damp patch does not identify which salts are present. Sampling may be needed.

Water vapour does not carry dissolved masonry salts through the wall. Salt transport with liquid water and moisture absorption by salts are distinct processes. Salts can also affect electrical moisture-meter readings, so a high reading alone is not proof of continuing water ingress.

A separate risk: condensation behind the board

Humid indoor air can reach a concealed space through gaps; water vapour can also move through materials. If conditions at a colder surface behind the lining reach the dew point, water can condense within the wall build-up. This is interstitial condensation. It is a different mechanism from liquid moisture crossing an adhesive dab.

Persistent dampness or high surface humidity can allow mould to grow on the paper backing, dust and other suitable material behind plasterboard—even before mould becomes visible in the room. Poorly designed linings can restrict drying or change temperatures within a wall. This is a risk, not an inevitable result of every dot-and-dab installation.

The photographs here do not show the back of the boards and do not confirm hidden mould, interstitial condensation or a particular salt. Inspection, environmental measurements and, where appropriate, opening up or moisture-risk assessment are needed to distinguish these causes.

When wet plasterboard needs removing

Prolonged or repeated wetting can soften the gypsum core, weaken the board, separate its paper facing and reduce the strength of gypsum adhesive. Mould can develop on porous paper surfaces, including the inaccessible rear face. Simply drying the visible surface or painting over it does not establish that the board, bond or concealed space is sound.

Water-damaged plasterboard generally needs replacing, particularly where it is softened, bowed, delaminated, mould-affected or contaminated. Removal also provides access to inspect the wall and allow affected layers to dry. Brief, clean surface wetting may be assessed differently; there is no single duration after which every board automatically fails. Follow the board manufacturer’s guidance and preserve the lining’s required fire and acoustic performance.

Fix the cause before rebuilding the finish

  1. Investigate rainwater entry, leaks, ground-related moisture, indoor humidity and the existing wall build-up—do not assume rising damp from patches alone.
  2. Arrange safe opening-up where needed, considering electrical services, dust, mould and any suspect older materials. Assess the concealed condition and any salt contamination.
  3. Repair the moisture source, remove unsuitable damaged materials and establish suitable drying conditions. Drying time depends on the construction and extent of wetting.
  4. Specify a compatible repair or lining system for the building and remaining moisture risks. Do not simply re-cover an unresolved damp wall or add a vapour barrier without assessing the complete build-up.
Thermal image showing surface temperature variations across a lined wall
Thermal imaging records surface temperature differences, not water content or salt type.
Thermal view showing rounded temperature patterns below a window
Patterns can help locate areas to investigate, including possible adhesive contact points; they are not a diagnosis by themselves.
Thermal image of contrasting surface temperatures around a window and electrical fittings
Temperature patterns must be checked against the construction, moisture measurements and other evidence.

These are investigation photographs from the Wimbledon property, not a completed repair sequence. No laboratory salt results or opened-up views of the board backing have been supplied. Thermal colours are relative to each image’s temperature scale and cannot prove moisture, salts or mould.

Chimney damp · Sulphates and salt contamination

Recurring chimney stains are not automatically rising damp.

Salt-contaminated chimney masonry can leave recurring damp-looking patches, damaged plaster and spoiled decorations—even after a fireplace is closed or a chimney breast has been removed and plastered over. We regularly encounter repeated replastering that covers the symptoms without dealing with the contamination.

Deteriorating painted wall beside an existing tiled fireplace
Patches and deterioration beside a chimney breast: investigate the cause before another coat of plaster or paint.
Surveyor taking a meter reading near damaged skirting and a stained wall beside a fireplace
Meter checks form part of the investigation. Salts can affect electrical readings; the displayed reading is not a laboratory moisture percentage for masonry.
Patchy wall finish above skirting beside a black tiled fireplace
Localised patches can follow chimney masonry, but their position alone does not establish the diagnosis.

Why old chimneys can remain salt-contaminated

Decades of combustion can leave deposits in flues and adjoining masonry. Chimney-related contamination can include chlorides, nitrates and sulphates. Some salts are hygroscopic: they absorb water vapour from humid indoor air, so patches can worsen in humid weather even without a new leak.

Sulphates are a family of salts, not one substance with a single behaviour. Some, such as ammonium sulphate, can contribute to hygroscopic dampness; other sulphates behave differently. Dissolved salts can move with liquid water and crystallise as it dries, damaging porous finishes. Neither appearance nor a handheld meter identifies the salt type—testing may be appropriate.

Removing a chimney breast does not necessarily remove all contaminated masonry: adjoining walls, retained flue sections or infill interfaces may still be affected. New plaster in contact with contaminated material can therefore develop symptoms again. This does not mean every removed chimney will cause a problem.

Signs worth investigating

  • Damp-looking patches following a chimney breast, an old flue line or the footprint of a removed fireplace.
  • White crystalline deposits, powdery or crumbling plaster, bubbling paint and repeated decorative failure.
  • Yellow or brown stains. Soot and tar can also cause staining, so these marks are not a chemical identification of salts.
  • Patches returning after ordinary replastering or changing with indoor humidity.
  • High electrical meter readings that need checking against the material, salts and other evidence.

Hygroscopic salt dampness is not rising damp. Rising damp involves liquid water moving upwards from the ground. Moisture attracted from the air by old chimney salts is a different mechanism and does not, by itself, justify an injected damp-proof course. More than one moisture source can exist, so the whole wall still needs assessing.

Why simply replastering can fail again

A fresh skim, ordinary gypsum plaster, filler or paint is not a salt-isolation system. Where liquid moisture carries salts into a new finish, or hygroscopic contamination remains in it, patches and deterioration can recur. Repeating the same covering work does not remove salts from the underlying masonry. A stain-blocking paint may hide discolouration temporarily without resolving the moisture mechanism.

Our approach: a suitable flexible plaster membrane system

Where an assessment confirms that salt isolation is needed and the wall is suitable, our preferred approach is a flexible plaster membrane system. A compatible salt-resistant membrane separates the new plaster finish from the contaminated background, helping prevent salts and associated moisture from migrating into the new finish.

This is physical isolation—not removal or neutralisation of the salts in the wall. It is a designed system, not simply a loose plastic sheet or another skim. Background preparation, the specified adhesive or fixings, joints, edges, service penetrations and plaster compatibility all matter. Different membrane products have different installation requirements.

A membrane is not automatically the best option for every building. Historic fabric, wall drying, remaining water entry, the extent of contamination and the complete wall build-up must be considered. Other compatible repair or isolation systems may be appropriate. We specify the approach after investigating, rather than promise that one product cures every chimney stain.

Investigate the chimney and moisture source first

  1. Review the chimney’s history, previous removals and repair work; inspect the pattern of damage and test materials where needed.
  2. Check for rain entry through chimney tops, pointing, flaunching and flashings, and assess condensation or inadequate ventilation in retained disused flues.
  3. Address active leaks and unsuitable flue conditions before specifying the internal repair. Do not automatically seal a disused flue airtight.
  4. Remove unsuitable contaminated finishes where necessary, then install the selected isolation and finishing system to its manufacturer’s requirements, with appropriate follow-up.

Fire safety matters: polymer membranes are not automatically suitable inside fireplaces or beside hot flues. Confirm product fire performance, appliance clearances and chimney construction with the appropriate specialist. Do not cover combustion-air vents, alter working flues or disturb electrical services. Chimney removal also requires appropriate structural advice.

More supplied photographs: staining, preparation and plastering stages
Wall return adjoining a black tiled fireplace and hearth
Returns, edges and adjoining finishes need considering when specifying a salt-isolation system.
Yellow-brown staining and flaking paint around a blanking plate above skirting
Staining, flaking and surface deposits are warning signs. Colour alone cannot distinguish salts, soot, tar or other causes.
Discoloured patches on the lower part of a painted wall above patterned flooring
Recurring patches on a decorated wall. Low-level staining is not, by itself, proof of rising damp.
Close view of patchy and damaged lower wall finish above white skirting
Replastering without addressing contamination can allow the same symptoms to return.
Preparation and lower-wall treatment around a chimney breast during building works
A supplied preparation-stage photograph. The particular products or concealed layers cannot be identified from this image alone.
Lower-wall works beside an opened fireplace during refurbishment
Work around a fireplace opening. A complete specification needs suitable treatment of boundaries, openings and adjoining finishes.
Plasterer applying a new finish to a chimney breast during works
A plaster-finishing stage. A fresh finish alone does not demonstrate that salt contamination or the moisture source has been resolved.

These photographs illustrate symptoms, inspection and work stages. No locations, laboratory salt results, named membrane product or long-term follow-up results have been supplied for this set. They do not establish the chemistry of a deposit or prove the performance of a concealed system.

Survey example · Wandsworth

A retaining garden wall feeding moisture towards the house.

During this Wandsworth survey, we found a garden wall abutting the house and retaining soil. Water from a gutter and downpipe was feeding moisture into this area, contributing to damp problems internally.

Why the outside details matter

Retained soil can keep adjoining masonry persistently wet. Where a garden wall meets the house, that contact can provide a route for moisture to transfer into the building. Rainwater discharged into the same area adds to the moisture load.

These junctions can also bypass moisture-resistant detailing, depending on the building’s construction and the relative ground levels. The wall connection, retained soil and rainwater drainage need assessing together—not simply covering the internal symptoms with paint or plaster.

What needs considering next?

  • Check where the gutter and downpipe discharge, and whether water reaches suitable drainage.
  • Assess the retained soil levels, wall-to-house junction and any moisture bridging.
  • Specify appropriate external repairs before allowing affected internal materials to dry and considering reinstatement.

This video records survey findings, not completed remedial work. Any alteration to a retaining wall or excavation beside the house needs an assessment of stability, drainage and neighbouring property—not an unplanned DIY removal.

How we investigate penetrating damp and water ingress
A survey example from Wandsworth, showing the external wall junction and affected internal area. Press play to watch with sound.
Earlsfield · Survey example

Ground-contact render, covered air bricks and misplaced rainwater discharge.

At this Earlsfield property, a sand-and-cement rendered plinth was in contact with the ground and bridging the damp-proof course (DPC) level. Air bricks serving the subfloor were covered, while the downpipe added moisture at the base of the house rather than directing it correctly into a gully.

This is not rising damp. The issues identified here were moisture bridging around the DPC, obstructed subfloor ventilation and rainwater being discharged incorrectly at the wall base—not rising damp through the house wall caused by a failed or absent DPC.

How these details can keep a building damp

  • A moisture bridge: porous render in contact with damp ground can draw up water by capillary action. Where it continues across the DPC level, it can create a route around that protective layer; this does not necessarily mean the DPC itself has failed.
  • Restricted drying: dense cement-rich render and incompatible surface coatings can slow evaporation from the underlying masonry. Ground contact and repeated wetting can therefore leave the wall base persistently damp.
  • Covered air bricks: obstructed subfloor vents reduce air movement beneath a suspended timber floor. This can slow drying and allow moisture to accumulate, increasing the risk of timber decay where damp conditions persist.
  • Extra rainwater at the wall base: a downpipe that does not discharge into suitable drainage can repeatedly wet the area, adding to the moisture load.

Investigate the external cause before choosing treatment.

Appropriate next steps include checking the downpipe and gully connection, assessing ground levels and DPC bridging, and restoring suitable subfloor ventilation. Any render removal, level changes or vent alterations need to suit the building and avoid damaging the masonry or creating a new route for water entry.

This is a survey example, not completed repair work. The video does not establish the condition of concealed floor timbers or prove that every internal symptom has the same cause. A bridged DPC should not automatically lead to chemical injection without assessing the bridge and other sources of moisture first.

About investigating water ingress and external moisture sourcesWatch what an air brick serving a subfloor should provide
External survey findings at an Earlsfield property. Press play to watch with sound.
Clapham · Project photographs

High ground levels: drainage, drying out and replastering.

High ground levels were identified on this Clapham job. Damp Proofing Services installed drainage, then the affected wall was dried out, re-rendered and plastered. These photographs show the internal wall through the repair stages.

Exposed brickwork beneath a bay window during damp remedial work in Clapham

Before: exposed brickwork

The affected bay-window wall stripped back before re-rendering.

New render coat below the same Clapham bay window before plastering

During: re-rendering

The lower wall with a new render coat, before the plaster finish.

Freshly plastered lower walls around the Clapham bay window

After: freshly plastered

The bay-window wall after replastering, before decoration.

The drainage installation is not pictured. The final photograph shows the plastering stage, not a decorated finish or a long-term follow-up.

Damp investigations in Clapham
Colliers Wood · Survey and remedial work

Bathroom extraction: tested, replaced and commissioned.

During a survey in Colliers Wood, Damp Proofing Services tested the bathroom extractor and found it was underpowered. A replacement fan was installed during the works, then tested and commissioned with the correct flow rates and functions checked.

Existing bathroom extractor fan above the shower in Colliers Wood

1. Existing extractor

The bathroom extractor was checked as part of the survey and found to be underpowered.

Airflow instrument displaying 8.58 litres per second during the Colliers Wood survey

2. Airflow testing

The survey photograph records an airflow reading of 8.58 litres per second.

Replacement Manrose extractor fan installed on the tiled bathroom wall in Colliers Wood

3. Replacement installed

A replacement bathroom extractor was installed during the works.

Airflow instrument displaying 15.17 litres per second during replacement fan commissioning

4. Tested and commissioned

The replacement was tested and commissioned, with flow rates and functions checked. This photograph records 15.17 litres per second.

The readings shown are from this job, not a universal target for every bathroom. Extraction requirements depend on the system and operating mode; these photographs are not a compliance certificate or evidence of a long-term condensation outcome.

About condensation, mould and ventilation investigations
Mortlake · Penetrating damp project

Repair advice, internal renovation plaster and a tidy handover.

At this Mortlake property, Damp Proofing Services identified a penetrating damp issue and advised which repairs needed to be carried out by the freeholder. Our internal work involved removing the affected plaster and re-rendering using Dryzone renovation plaster, ready for the customer’s plasterer to skim the room. We also cleaned up after the work.

Existing wall finishes beside the window before penetrating damp remedial work in Mortlake

Before: affected finishes

The lower wall and corner before the internal plaster was removed.

Wall and window corner in the Mortlake property before plaster removal

Before: the window wall

A wider view of the affected wall before our internal repairs.

Exposed brickwork around the Mortlake window after internal plaster removal

During: plaster removed

The affected plaster removed to expose the brickwork around the window.

New renovation plaster on the affected wall and window surround in Mortlake

During: renovation plaster

The internal repair using Dryzone renovation plaster, as specified for this job.

Mortlake wall repairs at the renovation plaster stage before the customer’s final skim

Our stage: ready for skimming

The repaired areas ready for the customer’s own plasterer to skim the room.

A member of the team vacuuming the Mortlake room after the internal remedial work

After our work: cleaning up

We also cleaned up after carrying out the internal work.

These photographs show our internal repair and clean-up stages. They do not confirm completion of the freeholder’s repairs, the customer’s final skim or decoration, or a long-term follow-up.

About penetrating damp investigations
Kensington · Basement waterproofing works

From wall membrane to freshly plastered recesses.

Photographs from basement waterproofing works carried out by Damp Proofing Services in Kensington. The sequence shows the wall membrane, framing, boarding and plastering, with the existing arched recesses retained.

Dimpled membrane fitted to basement walls and a column in Kensington

Wall membrane installation

Dimpled membrane fixed to the basement walls during the waterproofing works.

Timber framing over membrane around arched recesses in the Kensington basement

Framing around the recesses

Timber framing in front of the membrane, with the arched recesses retained.

Boarded walls with arched recesses during the Kensington basement project

Boarding stage

Wall boards fitted around the recesses ahead of plastering.

Fresh plaster on basement walls and arched recesses in Kensington

Freshly plastered walls

The photographed plastering stage, before decoration.

These photographs show stages of the works, not the complete waterproofing specification, a certification record or a long-term follow-up. The final photograph is before decoration.

About basement waterproofing investigations
Fulham · Survey finding

Interstitial condensation and moisture beneath the floor finish.

At this Fulham property, Damp Proofing Services identified an ongoing interstitial condensation issue linked to a lack of mechanical ventilation, high indoor humidity and moisture build-up. The survey photographs show the affected flooring, inspection beneath the finish and moisture-meter checks.

What does interstitial condensation mean?

It means moisture condensing within the layers of a building element, rather than only on its exposed surface. Investigating it involves considering ventilation, humidity, temperature and the construction together — not diagnosing the cause from a single meter reading.

Discoloured timber floor finish at the Fulham condensation investigation

Floor condition

An overview of the discoloured floor finish in the affected area.

Partly lifted timber flooring with exposed adhesive beside the wall in Fulham

Looking beneath the finish

Flooring lifted near the wall to inspect the layers beneath.

Exposed adhesive and staining beneath the lifted flooring near a Fulham room corner

The exposed floor layers

A closer view of the exposed adhesive and staining at the room perimeter.

Edge of a lifted flooring piece being examined at the Fulham property

Inspecting a lifted board

The edge of a lifted flooring piece examined during the investigation.

Pin moisture meter applied to a lifted flooring piece in Fulham

Checking the lifted material

A pin-meter check on the lifted flooring material as part of the survey.

Moisture meter placed on the timber floor finish during the Fulham survey

Checking the floor surface

A further moisture-meter check on the floor finish.

Moisture meter checking the floor beside the skirting in the Fulham property

Checking the perimeter

Another meter check near the skirting to compare conditions across the affected area.

This is a survey finding, not a completed repair or before-and-after result. Meter displays are interpreted in context; they are not room humidity readings and do not establish the moisture source on their own.

About condensation, mould and ventilation investigations
Ealing · Cold bridging and condensation

Insulating, reboarding and plastering.

Damp Proofing Services carried out insulation, reboarding and plastering work at this Ealing property to address cold bridging and condensation issues. The photographs show the strip-out, insulation and reboarding stages around the windows.

Exposed timber framing beneath the windows during condensation remedial work in Ealing

Strip-out: exposing the framing

Existing internal linings removed below the windows, exposing the timber framing.

Insulation boards fitted within exposed wall framing around windows in the Ealing property

During: insulation work

Insulation boards fitted between sections of the exposed framing during the works.

New internal wall boards around the Ealing windows before plastering

Reboarded: before plastering

New boards fitted around the windows. This photograph shows the stage before plastering.

The plastered finish is not pictured. These are work-stage photographs, not thermal performance measurements or a long-term follow-up.

About condensation and cold-surface investigations
Chiswick · Common defect

Failed pointing on an older solid-brick wall.

These photographs show weathered brickwork and mortar joints at a Chiswick property. Failed pointing is a common issue we find on surveys. On older solid walls without a cavity, the condition of the joints, bricks and nearby roof or window details all matter when investigating rainwater entry.

Why can hard cement pointing cause problems on a solid wall?

Many older solid-brick walls were built with softer bricks and lime mortar. If an incompatible, hard and relatively dense cement-rich mortar is used for repointing, it may be less able to accommodate movement. Cracks or gaps can develop along the joint and allow rainwater in. The harder joint may also slow drying through the mortar, so moisture and salts can be driven through the softer brick faces instead; over time this can contribute to flaking or spalling, particularly with frost.

Because a solid wall has no cavity separating its outer face from the inner masonry, persistent wetting can contribute to damp at internal finishes. Lime mortar is not a waterproof seal: a compatible mortar helps the wall manage moisture and movement. The right repair depends on the existing brick and mortar, exposure and other sources of water. Check the roof junction, rainwater goods and window details rather than assuming pointing is the only cause.

Weathered brickwork and mortar joints beside a window and roof in Chiswick

Brickwork at the corner

Weathered brickwork and joints beside a window and roof junction.

Close view of weathered mortar joints and brick faces on the Chiswick wall

Joints beside the window

A closer view of worn and uneven mortar joints in the wall face.

Chiswick brick wall and adjacent roof junction viewed along the masonry

The wider junction

The wall and adjoining roof detail, both relevant to tracing any rainwater entry.

The photographs illustrate a defect, not a completed repair. Mortar composition, the route of water entry and any internal effect cannot be confirmed from photographs alone.

About investigating penetrating damp

Brick cleaning, restoration and compatible lime repointing

More photographs from our work.

These additional photographs show inspection and repair stages from our wider work, rather than a single project sequence.

11 photographs

Full damp & timber survey

Want the same care on your home?

A proper investigation and a photographic written report — so whatever you spend next is spent on the actual cause. Contact us to discuss the current survey fee and availability.

What the survey covers

  • Internal inspection
  • External inspection
  • Moisture investigation
  • Thermal imaging where appropriate
  • Ventilation assessment
  • Accessible timber assessment
  • Photographs
  • Detailed written report
  • Recommended remedial actions
CallBook survey